Patch Panel CAT6A 24 Port RJ45 Shielded Network 19inch STP Vertical Punchdown

Introducing our premium 24 Port Vertical Punchdown CAT6A Patch Panel, the ultimate solution for or...

Best current price£46.74from B&Q

All Offers

2 offers from £46.74 - £48.58

View price history by clicking the chart icon.

B&QB&Q - 24 Port Shielded Network 19 Inch Patch Panel Cat6A Stp Vertical Punchdown
Free delivery in 1–3 days
£46.74
Visit shop
eBayPatch Panel CAT6A 24 Port RJ45 Shielded Network 19inch STP Vertical Punchdown
Free delivery in 1–3 days
£48.58
Visit shop

Product Information

Full details

This premium 24 Port Vertical Punchdown CAT6A Patch Panel is designed for businesses, data centers, and professional installations requiring organized, high-performance network infrastructure. It offers superior shielding for reliable connectivity and enhanced data transmission, with a caveat that a specific 110 type punch down tool is required for termination. Key features include a 1U height, 19-inch rack mountability, and color-coded ports for easy identification.

All features

Model Part NumberVPP-012445
Brandkenable

Extended Product Information

FAQs

What type of punch down tool do I need for this panel?

You will need a 110 type punch down tool for terminating the network cables onto the IDC modules on the rear of the panel.

Can I use stranded network cables with this patch panel?

This patch panel is designed for 22-26 AWG solid conductors. Using stranded cables is not recommended and may lead to poor connections or performance issues.

What is the difference between T568A and T568B wiring standards?

Both are industry standards for wiring Ethernet cables. T568B is more commonly used in North America, while T568A is also used. The key difference is the swapping of the green and orange wire pairs. It is crucial to use the same standard on both ends of a network cable run.

What does 'Shielded Twisted Pair' (STP) mean for this panel?

STP indicates that the patch panel has shielding designed to protect network signals from electromagnetic interference (EMI) and radio frequency interference (RFI), leading to more reliable data transmission, especially in noisy environments.

What is the height of this patch panel?

This patch panel has a height of 1U (Rack Unit), which is a standard measurement for equipment in server racks, equivalent to 1.75 inches.

How many ports does this patch panel have?

This patch panel features 24 RJ45 ports.

What is the warranty period for this product?

Please refer to the manufacturer's documentation or sales information for specific warranty details, as this information is not provided in the product description.

Troubleshooting

Network connection is slow or intermittent.

Verify that the correct 110 punch down tool was used and that all conductors are properly seated in the IDC modules. Check for correct T568A/T568B wiring on both ends. Ensure the CAT6A cables are within the specified 22-26 AWG solid conductor range and are not damaged.

Ports are not recognized by network devices.

Confirm that the network cable is fully punched down into the IDC module on the rear of the panel. Ensure the cable is correctly terminated according to the chosen wiring standard (T568A or T568B). Test the cable with a network cable tester.

Patch panel does not fit the rack.

Ensure the rack is a standard 19-inch width. The patch panel is designed to fit standard racks; verify that no obstructions are present in the mounting rails.

Pros and Cons

Pros

  • Enhanced data transmission speeds due to CAT6A support.
  • Superior shielding (STP) reduces interference and improves signal integrity.
  • Vertical punchdown design maximizes space in network cabinets.
  • Color-coded wiring standards (T568A/T568B) simplify installation and troubleshooting.
  • Durable construction ensures long-term reliability.

Cons

  • Requires a specific 110 type punch down tool for cable termination.
  • Solid conductors within the 22-26 AWG range are specified, limiting flexibility with stranded cables.
  • 1U height may be restrictive in extremely space-constrained environments if other 1U components are numerous.

Setup, Compatibility & Care

Setup:

  1. Mounting: Secure the patch panel into a standard 19-inch server rack or cabinet using appropriate mounting hardware.
  2. Cable Termination: Use a 110 type punch down tool to terminate network cables onto the IDC modules located on the rear of the panel. Follow the T568A or T568B color coding indicated on the IDC modules and the front of the panel for correct wiring.
  3. Connections: Connect network devices or patch cords to the RJ45 ports on the front of the panel.

Compatibility:

  • Compatible with 19-inch standard server racks and cabinets.
  • Designed for 22-26 AWG solid conductor network cables (e.g., CAT6A).
  • Supports T568A and T568B wiring standards.

Care:

  • Dust regularly with a soft, dry cloth. Avoid using liquids or abrasive cleaners.
  • Ensure proper ventilation around the rack to prevent overheating.
  • Periodically inspect connections for any signs of damage or corrosion.