This dial indicator has a 0-10mm dial in 0.01mm increments. The bezel around the front rim can be ...This dial indicator has a 0-10mm dial in 0.01mm increments. The bezel around the front rim can be rotated, carrying the scale with it - perfect for aligning the needle to point to zero. Features a puller for lifting the plunger. Specifications include a 0-10mm dial in 0.01mm increments and a rotating bezel. A magnetic stand can be purchased separately.
Us Pro Tools Metric Dial Test Indicator Gauge Precision Measuring 2657Free delivery in 1–3 days£11.38Visit shop →
Product Information
Full details
This US PRO Metric Dial Test Indicator Gauge (MPN: 2657) is designed for machinists and technicians who need precise measurements in 0.01mm increments. Its key benefit is the rotatable bezel for easy zeroing, allowing for quick relative measurements and alignment checks. A potential caveat is that the magnetic stand is sold separately, which is often a necessary accessory for easy mounting. This tool offers a 0-10mm measurement range with clear, fine graduations, and includes a plunger lift feature for convenience.
All features
Model Part Number
2657
Brand
us pro
Extended Product Information
FAQs
What is the primary purpose of the rotating bezel?
The rotating bezel allows you to easily align the dial's '0' with the needle, which is crucial for setting a reference point for comparative measurements. This means you can measure how much a surface deviates from a perfectly flat or aligned state.
Can I use this indicator for imperial measurements?
No, this indicator is specifically designed for metric measurements with a 0-10mm range and 0.01mm increments. For imperial measurements, you would need a different indicator with appropriate units.
Is a magnetic stand included with the indicator?
No, the magnetic stand is sold separately. You will need to purchase a compatible magnetic stand or other mounting solution to effectively use the indicator.
How do I calibrate this dial indicator?
Calibration typically involves professional equipment to verify accuracy against known standards. For typical workshop use, ensuring the bezel is set to zero and checking for consistent readings on a known flat surface is often sufficient. If precise calibration is required, consult a metrology service.
What is the smallest measurement change I can detect?
With increments of 0.01mm, you can detect changes as small as one-hundredth of a millimeter.
How should I clean the indicator?
Use a soft, dry cloth for regular cleaning. For tougher grime, a slightly damp cloth can be used, but be very careful to prevent any moisture from entering the internal mechanism. Ensure it is completely dry afterward.
What does 'MPN' stand for?
MPN stands for Manufacturer Part Number. In this case, 2657 is the unique part number assigned by US PRO to this specific model of dial test indicator.
Troubleshooting
Needle does not return to zero after plunger is released.
Check if the plunger is obstructed or if dirt has accumulated in the mechanism. Gently clean the plunger and ensure it moves freely. If the issue persists, the internal spring may be damaged.
Inconsistent or erratic readings.
Ensure the indicator is securely mounted and the surface being measured is clean and stable. Check for any play in the mounting or the plunger itself. Verify that the probe tip is clean and making proper contact.
Bezel is difficult to rotate.
Gently try to rotate the bezel. If it remains stiff, there might be debris. Avoid forcing it. A small amount of appropriate precision instrument lubricant might be needed, applied sparingly by a professional.
Plunger lift mechanism is stuck.
Ensure there is no external obstruction. Try gently wiggling the plunger while operating the lift. If it remains stuck, do not force it, as this may indicate an internal issue.
Pros and Cons
Pros
High precision with 0.01mm increments.
Rotating bezel simplifies zero setting for comparative measurements.
Integrated plunger lift adds user convenience.
Clear and easy-to-read dial.
Robust build quality suitable for workshop use.
Cons
Magnetic stand is not included and must be purchased separately.
Requires careful handling to maintain accuracy.
Limited measurement range compared to some other indicators.
Setup, Compatibility & Care
Setup:
Ensure the indicator is clean before first use.
If using with a magnetic stand (sold separately), attach the indicator securely to the stand's mounting post.
Position the indicator so the measuring tip contacts the surface to be measured.
Rotate the bezel to align the "0" on the dial with the needle for zeroing, or adjust as needed for comparative measurements.
Compatibility:
This indicator is compatible with standard dial indicator holders and magnetic stands.
It is designed for metric measurements.
Care:
Keep the indicator clean and free from dust and debris. Use a soft, dry cloth for general cleaning. For stubborn dirt, a slightly damp cloth can be used, ensuring no liquid enters the mechanism.
Avoid dropping or subjecting the indicator to shocks, as this can damage the delicate internal mechanism and affect accuracy.
Store the indicator in a protective case when not in use to prevent damage.
Periodically check the tip for wear and ensure it is clean.
When not in use for extended periods, retract the plunger to reduce stress on the spring.