AB Tools Regulator - Carbon Dioxide CO2 Single Stage 2 Gauge (Side Entry)

Precision engineered regulator for use with Carbon Dioxide (CO2). Features 50mm gauges conforming ...

Best current price£44.72from B&Q

All Offers

2 offers from £44.72

View price history by clicking the chart icon.

B&QB&Q - Carbon Dioxide Co2 Single Stage 2 Gauge Regulator (Side Entry) Gas Welding
Free delivery in 1–3 days
£44.72
Visit shop
eBayCarbon Dioxide CO2 Single Stage 2 Gauge Regulator (Side Entry) Gas Welding
Free delivery in 1–3 days
£44.72
Visit shop

Product Information

Full details

This guide is for welders and fabricators working with CO2 gas. The AB Tools CO2 Regulator offers precise gas flow control and clear monitoring with its dual gauges. A key benefit is its robust construction for reliable performance. However, it is specifically designed for CO2, limiting its use with other gases. Key features include a forged brass body, color-coded knobs for easy gas identification, and compliance with ISO standards for safety and quality.

All features

Model Part NumberEA012
BrandAB Tools

Extended Product Information

FAQs

What type of gas is this regulator for?

This regulator is specifically designed and calibrated for use with Carbon Dioxide (CO2) gas only.

What is the maximum cylinder pressure this regulator can handle?

The regulator has a maximum capacity of 300 Bar, suitable for standard high-pressure CO2 cylinders.

What is the maximum outlet pressure?

The maximum outlet pressure for this regulator is 4 Bar.

What does 'single-stage' mean for this regulator?

A single-stage regulator reduces cylinder pressure to a stable working pressure in one step. This design is generally simpler and effective for many CO2 applications.

How do I connect the regulator to the CO2 cylinder?

The regulator features a 5/8" BSP side-entry connection. Ensure the cylinder valve is closed, attach the regulator, hand-tighten, and then secure with a wrench. Slowly open the cylinder valve afterward.

Are the gauges accurate?

Yes, the 50mm gauges conform to ISO 5171 standards, ensuring accurate readings of cylinder and outlet pressure for precise control.

Can I use this regulator for Argon or other gases?

No, this regulator is calibrated exclusively for CO2. Using it with other gases can be unsafe and may damage the regulator.

Troubleshooting

Regulator not delivering gas

Ensure the cylinder valve is fully open. Check that the regulator is securely attached to the cylinder. Verify that the inlet connection is not blocked.

Gas leaks detected at connection

Close the cylinder valve immediately. Re-tighten the 5/8" BSP connection. If the leak persists, check the integrity of the cylinder valve and the regulator's inlet seal. Replace seal if damaged.

Pressure gauge not moving or stuck

Check if the cylinder contains gas. Ensure the cylinder valve is open and the regulator's T-handle is adjusted. If the gauge remains stuck, the regulator may require servicing or replacement.

Erratic or fluctuating outlet pressure

Ensure the T-handle is correctly adjusted. Check for leaks in the downstream hose or fittings. A single-stage regulator can be more sensitive to flow rate changes; ensure steady demand.

Pros and Cons

Pros

  • Durable forged brass construction for extended lifespan.
  • Clear, large gauges ensure easy monitoring of gas pressure.
  • Color-coding simplifies gas identification and enhances safety.
  • Designed specifically for reliable CO2 regulation.
  • Meets stringent ISO safety and performance standards.

Cons

  • Single-stage design may offer less fine control than dual-stage regulators for certain applications.
  • Limited to CO2 gas only; not suitable for other gas mixtures or types.
  • Side-entry connection may require specific cylinder valve orientations.

Setup, Compatibility & Care

Setup:

  1. Ensure the cylinder valve is fully closed.
  2. Attach the regulator to the CO2 cylinder using the 5/8" BSP connection. Hand-tighten firmly, then use an appropriate wrench for a secure fit (do not overtighten).
  3. Slowly open the cylinder valve. Listen for any leaks. If a leak is detected, close the valve immediately and re-seat the regulator.
  4. Gently open the T-handle on the regulator to achieve the desired outlet pressure, not exceeding 4 Bar.
  5. Always refer to your welding machine's manual for recommended CO2 pressure settings.

Compatibility:

  • Gas Type: Strictly designed for Carbon Dioxide (CO2) only.
  • Cylinder Connection: Compatible with standard CO2 cylinders featuring a 5/8" BSP side-entry connection.
  • Standards: Conforms to ISO 2503 and ISO 5171.

Care:

  • Keep the regulator clean and dry. Wipe with a slightly damp cloth if necessary; avoid abrasive cleaners.
  • Store in a well-ventilated area away from extreme temperatures and corrosive substances.
  • Regularly inspect the gauges and connections for any signs of damage or leaks.
  • Never use oil or grease on regulator fittings, as this can cause a dangerous reaction with oxygen or other gases (though less critical for pure CO2, it's good practice).
  • Periodically check that the inlet seal is intact and not damaged.

Price History

DatePrice
Visit shop