Connect Slotted M-Case Fuse - 40A - 2 Piece Set

Connect Slotted M-Case Fuse 40A 2 Piece Set - 34289. This pack contains 2x 40 amp M-Case slotted c...

Best current price£11.42from eBay

All Offers

3 offers from £11.42 - £13.87

View price history by clicking the chart icon.

eBayConnect Slotted M-Case Fuse 40A 2pc 34289
Free delivery in 1–3 days
£11.42
Visit shop

Product Information

Full details

This guide is for automotive and electrical system technicians and DIY enthusiasts needing reliable circuit protection. The Connect Slotted M-Case Fuse (40A, 2-piece set) offers robust protection for DC circuits up to 32V. While durable, users should ensure correct amperage rating for their specific application to prevent premature blowing or system damage.

All features

Model Part Number34289
BrandConnect

Extended Product Information

FAQs

What does 40A mean on this fuse?

40A stands for 40 Amps. This is the maximum current the fuse can safely handle before it intentionally blows to protect the circuit.

Can I use this fuse in a 24V system?

Yes, this fuse is rated for a maximum of 32V DC. It is suitable for 12V, 24V, and other DC systems up to 32V.

What is the difference between this fuse and a glass fuse?

This is an M-Case fuse with a plastic housing and a metal element, designed for higher current and more robust applications compared to smaller glass fuses. It also meets specific automotive standards (SAE J2741 & ISO 8820-4).

How do I know if I need a 40A fuse?

You should use a fuse with the amperage rating specified by the manufacturer of the electrical component or system you are protecting. Consult your device's manual or wiring diagram.

What material is the fuse element made of?

The fuse element is made of copper.

Is there a larger set available?

Yes, Connect also offers a 7-piece assorted set, Part No. 34292, which includes multiple fuse ratings.

What does RoHS & REACH compliant mean?

It means the product complies with regulations limiting the use of certain hazardous substances (RoHS) and the registration, evaluation, authorization, and restriction of chemicals (REACH), promoting environmental and health safety.

Troubleshooting

Fuse blows immediately after installation.

This indicates a short circuit or an overload in the protected system. Inspect the wiring for damage, ensure the accessory is functioning correctly, and verify that the 40A rating is appropriate for the circuit. Replace with a new fuse only after the underlying issue is resolved.

Fuse does not fit the fuse holder.

Verify that the fuse holder is designed for M-Case slotted cartridge fuses and that the fuse is correctly oriented. Ensure there is no debris or damage within the fuse holder terminals.

Fuse appears intact but circuit is not working.

The fuse may have a hairline fracture not visible to the naked eye. Test the fuse continuity with a multimeter or replace it with a known good fuse of the same rating.

Pros and Cons

Pros

  • Reliable circuit protection for 40A circuits.
  • Durable construction with copper and thermoplastic materials.
  • Meets recognized industry standards for safety and performance.
  • Convenient 2-piece set for immediate replacement needs.
  • Environmentally compliant with RoHS and REACH.

Cons

  • Limited to 32V DC applications, not suitable for higher voltage systems.
  • Specific 40A rating requires careful matching to the circuit's needs.
  • Only available as a 2-piece set, which might be more than needed for some users.
  • Assorted set (34292) is a separate purchase if multiple ratings are required.

Setup, Compatibility & Care

Setup: To install the fuse, ensure the circuit is de-energized (e.g., by disconnecting the battery). Remove the old fuse from its holder and insert the new Connect 40A fuse, ensuring it seats correctly. Re-energize the circuit. Always replace a blown fuse with one of the *exact same amperage rating*.

Compatibility: This fuse is compatible with electrical systems requiring a 40A rating and operating at a maximum of 32V DC. It is designed for use in fuse holders that accept M-Case slotted cartridge fuses conforming to SAE J2741 & ISO 8820-4 standards.

Care: Store fuses in a clean, dry place away from extreme temperatures. Avoid handling the fuse element directly. Periodically check fuse connections in the holder for corrosion or damage.

Price History

DatePrice
Visit shop