Interface Relay Module - 4CO 7A 24VDC - 58 Series

Complete interface relay assembly featuring push-in terminal connections with 4 changeover contact...

Best current price£17.04from Tameson UK

One Offer

1 offer from £17.04

View price history by clicking the chart icon.

Tameson UKFinder Interface Relay Module 4Co 7A 24Vdc With Led - 58.P4.9.024.0050
Free delivery in 1–3 days
£17.04
Visit shop

Product Information

Full details

This Finder 58 Series Interface Relay Module is designed for industrial control and automation applications, offering reliable switching for up to 4 independent circuits with a 7A/250VAC rating. It simplifies wiring with push-in terminal connections and provides clear status indication via an LED. A potential caveat is the fixed 24V DC coil voltage, requiring a compatible power supply.

All features

Series58 Series
Model Part Number58.P4.9.024.0050SMA
BrandFinder

Extended Product Information

FAQs

What type of wires can be used with the push-in terminals?

The push-in terminals are designed for solid conductors or finely stranded conductors with ferrule termination. Ensure the wire gauge is appropriate for the 7A current rating.

Can this relay switch AC and DC loads?

This relay is primarily rated for AC loads (250VAC at 7A). It can switch DC loads, but the maximum voltage and current ratings will be significantly lower. Always consult the product datasheet for specific DC load handling capabilities and derating.

What is the function of the varistor protection?

The integrated varistor acts as a surge suppressor, protecting the relay coil from transient voltage spikes that can occur in industrial power systems. This enhances the relay's lifespan and reliability.

How do I determine which contact is Normally Open (NO) and Normally Closed (NC)?

On the module or its datasheet, terminals are typically marked. For a 4CO relay, pairs like 1-2 (NC) and 1-4 (NO) represent one changeover contact. Terminal 1 is the common pole.

What is the switching frequency limit?

The maximum switching frequency depends on the load. For resistive loads, it's typically higher than for inductive loads. Refer to the product datasheet for specific switching frequency limits under various load conditions.

Is this relay suitable for safety-critical applications?

While designed for reliable industrial use, this specific interface relay module may not meet the stringent requirements for safety-critical functions (e.g., emergency stop circuits) without additional system design considerations and certifications. Always consult relevant safety standards and product certifications.

Troubleshooting

Relay does not energize when coil voltage is applied.

Verify the 24V DC coil voltage supply is correctly connected to A1/A2 and meets voltage specifications. Ensure wires are securely seated in the push-in terminals. Check the LED indicator; if it's off, the issue is likely with the coil circuit or power supply.

Contacts do not switch (remain open or closed).

Confirm the coil is energized (LED is on). Check that the load wiring is correctly connected to the appropriate NO (Normally Open) or NC (Normally Closed) contacts. Ensure the load current does not exceed the 7A rating.

Intermittent operation or poor contact reliability.

Ensure the wire connections are clean, solid, and properly inserted. Check for any signs of arcing or overheating at the terminals. Verify the input voltage is stable and within tolerance. If switching inductive loads, ensure appropriate suppression (e.g., flyback diode, varistor) is present if not integrated.

LED indicator is not lighting up.

Double-check the polarity and connection of the 24V DC coil power supply. Ensure the supply voltage is present and correct. If the LED is burnt out, the relay may still function, but visual status indication will be lost.

Pros and Cons

Pros

  • Quick installation due to push-in terminals.
  • High switching capacity for various loads.
  • Clear status indication via LED.
  • Robust design with varistor protection.
  • Compact footprint for DIN rail mounting.

Cons

  • Fixed coil voltage (24V DC) requires specific power supply.
  • Not suitable for applications requiring AC coil control.
  • Push-in terminals may require careful wire preparation.
  • Limited to 4 changeover contacts; may not suit complex switching needs.

Setup, Compatibility & Care

Setup:

  1. Mounting: Securely attach the module to a standard 35mm DIN rail.
  2. Wiring: Insert solid or finely stranded conductor wires (stripped to the correct length) directly into the push-in terminals. Ensure a firm connection. Refer to the wiring diagram on the module or datasheet for correct terminal assignments.
  3. Power Supply: Connect a stable 24V DC power source to the designated coil input terminals (typically marked A1 and A2).
  4. Load Connections: Wire the devices to be controlled to the appropriate contact terminals (typically marked 1-2, 1-4, 2-3, 2-5, etc., for the changeover contacts).

Compatibility:

  • Coil Voltage: Compatible only with 24V DC power sources.
  • Load Type: Suitable for resistive and inductive AC loads within the 7A/250VAC rating. For DC loads, consult the datasheet for derating information.
  • Environment: Designed for industrial environments; avoid excessive moisture, dust, or extreme temperatures beyond specified operating limits.

Care:

  • Cleaning: Disconnect power before cleaning. Use a dry or slightly damp cloth to wipe the exterior. Avoid solvents or abrasive cleaners.
  • Inspection: Periodically inspect connections for security and signs of wear or overheating. Ensure ventilation around the module is unobstructed.