Sensor/actuator plug-in connector, 4-position, Plug straight, M8, A-coded, Insulation displacement...Sensor/actuator plug-in connector, 4-position, Plug straight, M8, A-coded, Insulation displacement connection. Knurl material: Nickel-plated brass. External cable diameter 2.5 mm ... 5 mm. Phoenix Contact manufactures the sensor/actuator plug-in connector SACC-M 8MS-4QO-0,5-M 1441037, known for its robust build and reliable performance. This connector features a quick-connect system that facilitates easy installation and maintenance in automated systems. It is typically used in industrial settings for connecting sensors and actuators to control units.
Best current price£4.39from Rapid Online - Rapid Electronics Ltd.
Phoenix Contact 1411043 SACC-M12MSX-8QO SH ETH Data ConnectorFree delivery in 1–3 days£15.00Visit shop →
Phoenix Contact Data Connector SACC-M12MSD-4QO SH PN 1411068£29.27 delivery£27.05Visit shop →
Product Information
Full details
The Phoenix Contact 1441037 is a 4-position M8 sensor/actuator plug designed for robust industrial applications. It offers a quick, time-saving insulation displacement connection (IDC) for reliable signal transmission in automated systems. A potential caveat is that the IDC method requires specific tools and careful execution for optimal results. Key features include its A-coded M8 straight plug design, IP65 protection, and compatibility with cable diameters from 2.5 mm to 5 mm.
All features
Model Part Number
1441037
Brand
Phoenix Contact
Extended Product Information
FAQs
What does 'A-coded' mean for an M8 connector?
A-coding is a standard pin assignment for M8 connectors, typically used for basic sensor/actuator signals. For a 4-position connector, it usually designates specific pins for power (V+), ground (0V), and signal channels.
What is Insulation Displacement Connection (IDC)?
IDC is a method of electrical connection where a specially designed terminal pierces the insulation of a wire, creating a gas-tight connection without prior stripping of the conductor. It's known for speed and eliminating the need for crimping tools.
Can I use this connector with different wire gauges?
The connector is designed for specific cable diameters (2.5 mm to 5 mm). Within that range, the IDC technology is intended to accommodate standard conductor sizes typically found in sensor/actuator cables.
What is the operating temperature range for this connector?
The Phoenix Contact 1441037 connector is rated for operation between -25 °C and 80 °C.
How do I ensure the IP65 rating is maintained?
The IP65 rating is maintained when the connector is properly mated with a compatible receptacle and the cable is correctly terminated and sealed within the connector's strain relief/grommet.
Is this connector suitable for high-current applications?
M8 connectors, including this one, are generally designed for signal transmission and lower power applications. For higher current requirements, an M12 connector might be more appropriate.
What material is the knurl made of?
The knurl material for this connector is nickel-plated brass, providing durability and corrosion resistance.
Troubleshooting
Connection fails after assembly
Verify that wires were correctly seated in the IDC slots and that the connector housing was fully closed. Ensure the cable diameter is within the specified range (2.5-5 mm).
Signal intermittent or noisy
Check for proper seating of the plug into the receptacle. Inspect the IDC terminations for any potential damage or loose connections. Ensure the cable is not bent sharply near the connector.
Connector does not mate with receptacle
Confirm that both the plug and receptacle are M8 size and have the same A-coding. Ensure no debris is obstructing the mating surfaces.
Connector exposed to water/dust ingress
Inspect the connector seal and housing for any damage. Ensure the cable is properly sealed within the connector grommet. If damage is found, the connector may need replacement.
Pros and Cons
Pros
Fast and tool-less wire termination with IDC technology.
High ingress protection (IP65) for harsh industrial environments.
Durable construction with nickel-plated brass components.
Versatile with support for a range of cable diameters.
Cons
IDC termination requires precision and may have a learning curve.
Specific tools may be needed for optimal IDC connection.
Limited to 4 positions, which may not suit all complex sensor arrangements.
M8 size is suitable for lighter-duty signals; M12 might be needed for higher current/data needs.
Setup, Compatibility & Care
Setup:
Ensure the cable's outer diameter is within the 2.5 mm to 5 mm range.
Prepare the cable end. For IDC, the connector's internal insulation displacement mechanism pierces the wire insulation to create the connection. Specific tools may be recommended by Phoenix Contact for optimal IDC performance.
Insert the wires into the designated slots within the connector.
Close the connector housing to complete the insulation displacement process.
Connect the straight M8 plug to a corresponding M8 receptacle on your control system or device.
Compatibility:
This connector is M8, 4-position, and A-coded, designed to mate with standard M8 A-coded receptacles.
It is compatible with sensors and actuators requiring a 4-pin connection.
Suitable for use with cables having an external diameter between 2.5 mm and 5 mm.
Care:
Clean the connector exterior with a dry or slightly damp cloth. Avoid using solvents or abrasive cleaners.
Periodically inspect the connector for any signs of physical damage or contamination. Ensure the connection is secure.