Kenable Outdoor External Network Cable Ethernet Patch Lead - CAT5E-CCA

Upgrade your outdoor network infrastructure with our Outdoor External CAT5E-CCA UTP Network Cable ...

Best current price£7.99from B&Q

All Offers

3 offers from £7.99 - £8.21

View price history by clicking the chart icon.

B&QB&Q - Outdoor External Cat5E-Cca Utp Network Cable Ethernet Patch Lead Pe Jacket 15M
Free delivery in 1–3 days
£7.99
Visit shop
OnBuy.comKenable Outdoor External Cat5e-Cca Utp Network Cable Ethernet Patch Lead Pe Jacket 15M
Free delivery in 1–3 days
£8.21
Visit shop

Product Information

Full details

This Kenable Outdoor External CAT5E-CCA UTP Network Cable is designed for users needing to extend their network connections outdoors reliably. Its key benefit is providing durable, weather-resistant connectivity for devices like IP cameras or outdoor Wi-Fi access points. A potential caveat is that CCA (Copper-Clad Aluminum) conductors may not offer the same performance over very long distances or in highly demanding network environments compared to pure copper. The cable features CAT5E performance, UTP construction, and a protective PE jacket, all within a 15-meter length for convenient outdoor deployment.

All features

SeriesCAT5E-CCA
Model Part Number012556
Brandkenable

Extended Product Information

FAQs

Is this cable suitable for burying directly underground?

While the PE jacket offers weather resistance, this cable is not specifically rated for direct burial. For underground applications, consider using a cable with a more robust, waterproof, and rodent-resistant jacket designed for direct burial.

Can I use this cable for PoE (Power over Ethernet) devices?

This cable is designed for data transmission. While it might support some lower-power PoE devices, it is not specifically optimized or rated for high-power PoE applications. For reliable PoE, it's recommended to use cables specifically designed and rated for PoE.

What is the difference between CAT5E-CCA and CAT5E-Pure Copper?

CAT5E-CCA uses a core of aluminum wrapped in a thin layer of copper. CAT5E-Pure Copper uses solid copper conductors. Pure copper offers better conductivity, flexibility, and performance over longer distances and is generally more resistant to fatigue and breakage. CCA is more cost-effective but can have higher resistance and may not perform as well in demanding or long-distance applications.

How does the UTP (Unshielded Twisted Pair) construction affect performance outdoors?

UTP construction is standard for Ethernet. Outdoors, it means the cable is more susceptible to electromagnetic interference (EMI) from sources like power lines or heavy machinery compared to shielded cables (STP/FTP). However, for typical residential or small office outdoor uses where EMI is not extreme, UTP is usually sufficient.

Will this cable work with my existing network equipment?

Yes, as long as your network equipment has standard RJ45 Ethernet ports, this CAT5E cable will be compatible. It supports the standards used by most modern networking devices.

What is the maximum recommended length for this cable?

The CAT5E standard itself is designed for a maximum length of 100 meters (328 feet). However, this specific cable is 15 meters long. For CCA cables, performance can degrade over longer distances more significantly than with pure copper, so it's best used for the intended shorter outdoor runs.

Troubleshooting

No network connection after installation

Verify that both ends of the cable are securely plugged into the correct ports. Check the indicator lights on your network devices. Test the cable with a known working device if possible. Ensure the cable is not damaged.

Slow or intermittent network speeds

Check for potential interference from other electronic devices or power cables. Ensure the cable is not kinked or severely bent. Verify that your connected devices support Gigabit Ethernet if you expect those speeds. Consider if the CCA construction is limiting performance for your specific use case.

Cable appears damaged or degraded

If the PE jacket shows signs of cracking, fraying, or UV damage, the cable's integrity may be compromised. Replace the cable to ensure reliable performance and prevent potential water ingress.

Pros and Cons

Pros

  • Specifically designed for outdoor use with weather-resistant features.
  • Cost-effective due to CCA conductor material.
  • Provides adequate CAT5E performance for many outdoor applications.
  • Durable PE jacket offers good protection against environmental factors.
  • Convenient 15-meter length for common outdoor setups.

Cons

  • CCA conductors may not perform as well as pure copper over longer distances or in high-interference scenarios.
  • UTP construction offers less protection against electromagnetic interference (EMI) compared to shielded cables.
  • Limited to 15 meters, not suitable for very long outdoor runs.
  • May not meet the highest performance standards required for critical, high-bandwidth outdoor networks.

Setup, Compatibility & Care

Setup:

  1. Plan Your Route: Determine the shortest and safest path for the cable, avoiding sharp bends or potential damage points.
  2. Connect One End: Plug one end of the cable into your network device (router, switch, camera, access point).
  3. Connect the Other End: Plug the other end into its corresponding network device.
  4. Secure the Cable: Use appropriate outdoor-rated cable clips or ties to secure the cable, preventing it from sagging or being pulled.

Compatibility:

  • Standard Ethernet Ports: Compatible with any standard RJ45 Ethernet port found on routers, switches, computers, IP cameras, and Wi-Fi access points.
  • CAT5E Standard: Fully compliant with the CAT5E standard, supporting speeds up to 1000 Mbps (Gigabit Ethernet) over distances up to 100 meters (though this specific cable is 15 meters).

Care:

  • Cleaning: Wipe the exterior jacket with a slightly damp cloth if it becomes dirty. Avoid harsh chemicals or abrasive cleaners.
  • Inspection: Periodically inspect the cable for any signs of wear, damage, or degradation, especially at connection points or where it is exposed to the elements.
  • Avoid Stress: Ensure the cable is not under continuous tension or subjected to excessive pulling.

Price History

DatePrice
Visit shop