This WCED Consumer Unit (WMEPME10/LB) is designed for Electric Vehicle (EV) chargers that lack integral PME protection, earth leakage protection, overload protection, and require load management. Its key benefit is the automatic monitoring and isolation of the electrical supply during voltage fluctuations, ensuring charger and system safety. A caveat is that over-voltage events require manual reset. It features integrated RCBO, SPD, and load balancing capabilities, alongside automatic voltage monitoring across 230V and 240V systems.

All features

Model Part NumberWMEPME10/LB
BrandWCED

Extended Product Information

FAQs

What is PME protection and why is it important for EV chargers?

PME (Protective Multiple Earning) protection is a safety feature that helps to ensure that the earthing system remains effective. Some EV chargers require this protection to be built-in or provided externally.

What is the voltage range for normal operation?

The unit operates normally between 207V and 253V AC. It will isolate the supply if the voltage falls below 207V or rises above 253V.

How long does it take for the unit to isolate the supply during voltage issues?

The unit will isolate the Live, Neutral, and Earth within 4 seconds of detecting an under-voltage or over-voltage condition.

Do I need a separate RCBO and SPD?

No, this WCED consumer unit integrates an RCBO (Residual Current Breaker with Overcurrent protection) and an SPD (Surge Protection Device) into a single unit, simplifying installation.

What is load management in this context?

Load management refers to the unit's ability to manage the electrical load, potentially preventing overload conditions and ensuring stability, especially relevant when supplying high-demand devices like EV chargers.

Can this unit be used with any EV charger?

This unit is specifically designed for EV chargers that *do not* have integral PME protection, earth leakage protection, and overload protection. It is not suitable for chargers that already include these features.

What is the rated current for this consumer unit?

The rated current for this consumer unit is 40A.

Troubleshooting

Unit is not powering the EV charger.

Check that the main power supply to the consumer unit is on and within the normal operating voltage range (207V-253V). Verify all connections are secure. Ensure the reset button hasn't been tripped by an over-voltage event.

Unit repeatedly isolates the supply.

This may indicate persistent under-voltage or over-voltage conditions. Check your main power supply stability. Consult your electricity provider if the issue is ongoing. Ensure the EV charger's load does not exceed the unit's 40A rating.

Over-voltage isolation occurred, but the unit will not reset.

Confirm that the supply voltage has returned to the normal operating range (207V-253V). Press the "RED" reset button firmly. If the issue persists, a qualified electrician should inspect the unit and supply.

Under-voltage isolation occurred, and the unit did not reset automatically.

Ensure the supply voltage has returned to the normal operating range. If it remains low, the unit will not reset. If the voltage is within range and it still doesn't reset, contact a qualified electrician.

Pros and Cons

Pros

  • Provides essential safety protection for EV chargers lacking built-in features.
  • Automated voltage monitoring and isolation prevent damage from power fluctuations.
  • Dual functionality of automatic and manual reset caters to different voltage event types.
  • Space-saving integration of RCBO, SPD, and load balancing.
  • Robust protection with a 16kA short circuit rating.

Cons

  • Requires manual intervention to reset after an over-voltage event.
  • Not suitable for EV chargers with integral PME, earth leakage, or overload protection.
  • Installation requires qualified electrical knowledge.

Setup, Compatibility & Care

Setup:

This unit should be installed by a qualified electrician following all relevant wiring regulations. It is designed to be integrated into an existing electrical distribution system, typically serving as a dedicated supply for an EV charger.

Compatibility:

  • Ideal for: EV chargers that *do not* have integral PME protection, earth leakage protection, and overload protection, and require load management.
  • Voltage: Compatible with 230V AC and 240V AC supplies.
  • Frequency: Operates on 50/60Hz.
  • Rated Current: Suitable for circuits up to 40A.

Care:

  • Cleaning: Disconnect the main power supply before cleaning. Use a dry or slightly damp cloth to wipe the exterior of the unit. Avoid using solvents or abrasive cleaners.
  • Inspection: Periodically inspect the unit for any signs of damage or wear. Ensure connections remain secure.
  • Reset Button: Familiarize yourself with the location and function of the "RED" reset button for over-voltage events.