Outdoor PE Jacket Cat 6 Gigabit Cable with snag less ends to avoid damaging the latch. 24 AWG High...Outdoor PE Jacket Cat 6 Gigabit Cable with snag less ends to avoid damaging the latch. 24 AWG High Quality FULL COPPER cable. Outdoor rated cables are suitable for burying or being left exposed to the elements due to the jacket. The PE jacket is weatherproof and UV resistant ensuring they do not erode over the years. We recommend a trunking if you are burying these cables as they are not spade proof. High Quality Cable using top of the selection 24AWG Copper cable ISO/IEC 11801 & EN 50288 & TIA EIA-568-B.2-1 ETL/3P Verified E164469-F3 Definition: CAT6 is an Ethernet cable standard defined by the Electronic Industries Association and Telecommunications Industry Association (commonly known as EIA/TIA). CAT6 is the 6th generation of twisted pair Ethernet cabling. CAT6 cable contains four pairs of copper wire and unlike CAT5 utilizes all four pairs. CAT6 supports Gigabit (1000 Mbps) Ethernet and supports communications at more than twice the speed of CAT5e the other popular standard for Gigabit Ethernet cabling. Another tip is to check you have a connection that you are happy with BEFORE you install / Run any cables. Outdoor Polyethylene jacket (Water tight and UV Resistant) Cable OD: 6mm Snagless Ends Cat 6 Gigabit (1000mbps Speeds).
This Kenable CAT6 outdoor network cable is designed for users needing a reliable Gigabit Ethernet connection in demanding external environments. Its key benefit is providing high-speed data transfer (1000 Mbps) with robust protection against weather and UV exposure. A caveat to consider is that while the PE jacket is weatherproof, the cable is not spade-proof, recommending trunking for underground installations.
All features
Series
CAT6
Model Part Number
11268
Brand
kenable
Extended Product Information
FAQs
Can this cable be buried directly in the ground?
Yes, the outdoor PE jacket is designed to withstand burial. However, it is not spade-proof, so using a protective conduit or trunking is strongly recommended to prevent damage from digging.
What speeds does this CAT6 cable support?
This cable supports Gigabit Ethernet speeds of up to 1000 Mbps (1 Gbps).
Is this cable suitable for indoor use?
While it can be used indoors, it is specifically designed for outdoor use with a more robust jacket. For purely indoor applications, a standard indoor CAT6 cable might be more cost-effective and easier to manage.
What does 'UTP' stand for?
UTP stands for Unshielded Twisted Pair. This cable uses twisted pairs of wires but does not have an additional metallic shielding layer.
What is the diameter of the cable?
The cable has an outer diameter (OD) of 6mm.
How do I ensure a good connection when terminating the cable myself?
Ensure you strip the outer jacket carefully without nicking the inner wires. Untwist each pair only as much as necessary, arrange them in the correct T568A or T568B order, insert them fully into the RJ45 connector, and use a proper crimping tool to secure the connection.
Is this cable compatible with PoE (Power over Ethernet)?
Yes, this CAT6 cable is suitable for use with Power over Ethernet (PoE) devices, provided the connected equipment supports it.
Troubleshooting
No network connection after installation
Verify that both ends of the cable are securely plugged into the devices. Double-check the wire termination at the RJ45 connectors for correct order and connection. Test with a shorter, known working cable to isolate the issue.
Slow network speeds or intermittent connection
Ensure the cable is properly terminated and undamaged. Check that connected devices support Gigabit speeds. Inspect for any kinks, sharp bends, or damage to the cable jacket that might compromise the internal wires. Verify that the cable is not running parallel and too close to high-voltage power cables, which can cause interference.
Connector latch broken
The snagless boot is designed to protect the latch during connection and disconnection. If the latch is still broken, the connector may need to be replaced. Re-terminate the cable end with a new CAT6 RJ45 connector.
Cable fails continuity test
This indicates a break in one or more internal wires or a faulty connection at the RJ45 plugs. Re-examine the termination at both ends or re-terminate if necessary. Use a cable tester to pinpoint the exact fault.
Pros and Cons
Pros
Durable outdoor-rated jacket provides excellent weather and UV resistance.
Snagless connectors prevent damage to the cable's latch.
Meets industry standards and is ETL/3P verified for quality assurance.
Suitable for direct burial or exposed outdoor runs.
Cons
Not spade-proof, requiring protective trunking if buried.
Cable diameter of 6mm may be restrictive in some conduit sizes.
Requires proper termination for optimal performance.
Setup, Compatibility & Care
Setup:
Plan your run: Determine the most direct and protected route for the cable, considering potential obstacles and the need for trunking if burying.
Terminate the cable: If you are using raw cable and need to create custom lengths or connections, use appropriate CAT6 RJ45 connectors and a crimping tool. Ensure all 8 wires are correctly terminated according to the TIA/EIA-568-B.2-1 standard (either T568A or T568B at both ends).
Connect devices: Plug the pre-terminated ends of the cable into your network devices (router, switch, computer, camera, etc.).
Compatibility:
Network Standards: Fully compatible with Gigabit Ethernet (1000BASE-T) and backward compatible with Fast Ethernet (100BASE-TX).
Devices: Works with any standard networking equipment that uses RJ45 Ethernet ports, including routers, switches, modems, computers, game consoles, and IP cameras.
Outdoor Installations: Designed for direct burial (with protective conduit recommended) or aerial deployment where exposed to the elements.
Care:
Cleaning: Wipe the exterior PE jacket with a slightly damp cloth to remove dirt or debris. Avoid using harsh chemicals or solvents.
Inspection: Periodically inspect the cable for any signs of physical damage, such as cuts, abrasions, or damaged connectors, especially at connection points.
Protection: If buried, ensure the trunking remains intact. If exposed, protect the cable from sharp objects or excessive tension.