Kern ORA 4FA Analogue Refractometer - EG/PG/CW/BF

The Kern ORA 4FA refractometer measures the concentration of various industrial and automotive sol...

Best current price£67.07from Rapid Online - Rapid Electronics Ltd.

All Offers

6 offers from £67.07 - £97.15

View price history by clicking the chart icon.

Rapid Online - Rapid Electronics Ltd.Kern ORA 4FA Analogue Refractometer EG/PG/CW/BF
Free delivery in 1–3 days
£67.07
Visit shop

Product Information

Full details

The Kern ORA 4FA is a universal, maintenance-free analogue manual refractometer designed for measuring the concentration of various industrial and automotive solutions. It is ideal for professionals needing accurate readings of AdBlue, glycol (EG & PG), battery fluid, and screen wash freezing points, offering a practical and robust solution for frequent use in production environments. Its primary benefit is the elimination of user calculation errors through built-in, calibrated scales. A potential caveat is that it is an analogue device, requiring manual operation and interpretation.

All features

Model Part NumberORA 4FA
BrandKern

Extended Product Information

FAQs

What types of fluids can the Kern ORA 4FA measure?

The ORA 4FA is designed to measure the concentration of AdBlue, ethylene glycol (EG), propylene glycol (PG), battery fluid (BF), and the freezing point of screen wash (CW).

Does this refractometer require batteries?

No, the Kern ORA 4FA is an analogue manual refractometer and does not require batteries or any power source.

How do I clean the refractometer?

Clean the prism and cover plate with a soft, damp cloth after each use. Dry thoroughly with a soft, lint-free cloth. Avoid abrasive cleaners or solvents.

Can I use this to measure salinity?

No, the ORA 4FA is not designed for salinity measurements. A different model, like the Kern ORA 1SA, would be required for that purpose.

What is the benefit of the built-in calibrated scales?

The built-in scales eliminate the need for manual conversion of refractive index values into concentration units, thereby preventing user calculation errors and ensuring faster, more accurate results.

Is the ORA 4FA suitable for continuous use in a factory setting?

Yes, its robust and maintenance-free design makes it suitable for repeated use in production environments.

What is the warranty period for the Kern ORA 4FA?

Please refer to the manufacturer's documentation or the retailer for specific warranty information, as it can vary.

Troubleshooting

Unclear or blurry scale reading.

Ensure the eyepiece is clean and properly focused. Check that the sample fluid is spread evenly on the prism without air bubbles. Ensure sufficient light is available.

Reading appears consistently incorrect.

Verify that the correct scale is being used for the fluid being tested. Ensure the instrument was properly cleaned after the previous use. Recalibrate using distilled water if possible and if the issue persists.

Fluid does not spread evenly on the prism.

Ensure both the prism and the cover plate are perfectly clean. Apply a sufficient amount of sample fluid, and close the cover plate gently to avoid trapping air.

Pros and Cons

Pros

  • Eliminates calculation errors with integrated scales.
  • Durable construction suitable for industrial use.
  • No power source required, enhancing portability and reliability.
  • Simple and intuitive operation for quick measurements.
  • Versatile for a range of automotive and industrial fluid analyses.

Cons

  • Analogue display may be less precise than digital counterparts.
  • Requires manual operation and direct light for reading.
  • Limited to specific fluid types for which scales are calibrated.
  • Not suitable for applications requiring data logging or connectivity.

Setup, Compatibility & Care

Setup:

  1. Ensure the refractometer prism and the sample surface are clean.
  2. Place a few drops of the fluid to be tested onto the prism.
  3. Close the cover plate gently, ensuring the fluid spreads evenly without air bubbles.
  4. Point the eyepiece towards a light source (natural daylight is recommended).
  5. Focus the eyepiece until the scale is sharp and clear.

Compatibility:

This refractometer is specifically calibrated for:

  • AdBlue (Urea solution)
  • Ethylene Glycol (EG)
  • Propylene Glycol (PG)
  • Battery Fluid (BF)
  • Screen Wash (CW - freezing point)

It is not designed for use with other substances unless they share a similar refractive index behavior and fall within the calibrated range for one of the supported scales.

Care:

  • Cleaning: After each use, clean the prism and cover plate immediately with a soft, damp cloth. Use distilled water if necessary. Dry thoroughly with a soft, lint-free cloth. Never use abrasive materials or harsh solvents, as they can damage the prism surface.
  • Storage: Store the refractometer in its original case in a dry, protected environment. Avoid extreme temperatures and direct sunlight for extended periods.
  • Calibration: The device is factory-calibrated. For critical applications, periodic recalibration with distilled water and a known standard may be advisable, though typically not required for routine use.