HENSEL KF 1616 G Terminal Box - Grey Polycarbonate - 210 x 155mm

This HENSEL KF Series terminal box is constructed from grey polycarbonate, offering robust protect...

Best current price£146.95from eBay

One Offer

1 offer from £146.95

View price history by clicking the chart icon.

eBayJunction Box N/T 5x16mm² 210x155x92mm GLUE CASE KF 1616 G
£11.00 delivery
£146.95
Visit shop

Product Information

Full details

The HENSEL KF 1616 G terminal box is designed for electricians and installers seeking a durable and weather-resistant enclosure for electrical connections. Its primary benefit is robust protection against environmental factors, ensuring reliable performance in demanding conditions. A key consideration is that while it offers multiple entry options, some may require separate ordering of accessories. This box provides secure and versatile wiring with a high rated insulation voltage, making it suitable for various industrial and outdoor applications.

All features

Model Part NumberKF 1616 G
BrandHENSEL

Extended Product Information

FAQs

What is the maximum conductor size this box can accommodate?

The terminal clamp supports a maximum conductor cross-section of 25mm². The internal terminal blocks offer configurations for various sizes from 6mm² up to 35mm², depending on the conductor type (solid/flexible) and use of ferrules.

Is this box suitable for direct outdoor exposure?

Yes, the HENSEL KF 1616 G has IP66, IP67, and IP69 ratings, and is described as 'weatherproof' and 'saltwater-proof', making it highly suitable for direct outdoor exposure and demanding environmental conditions.

Does the box come with cable glands?

The box features two pre-made M32 cable entries from the rear and knockouts for additional entries. However, specific cable glands (like AKM or LES series) are often ordered separately to ensure proper sealing.

Can the lid be secured against tampering?

Yes, the lid fasteners are designed to be sealable without the need for additional accessories, providing a basic level of tamper resistance and environmental security.

What is the operating temperature range?

The box is designed for working temperatures between -25°C and 70°C.

Is the material halogen-free?

Yes, the product description states that the box is halogen-free.

How is the box mounted?

The box is designed for surface-mounted wall or ceiling applications and includes external brackets for easy installation.

Troubleshooting

Cover seal appears compromised

Inspect the cover seal for damage or debris. Clean the sealing surfaces and re-tighten the cover screws evenly. If damaged, consider replacing the seal if possible or the entire unit.

Water ingress detected inside the box

Immediately disconnect power. Inspect all cable entries and the cover seal for potential entry points. Ensure all cable glands are properly tightened and sealed. Check for any cracks in the box itself. If the cause isn't obvious, replace the unit.

Difficulty inserting cable through knockouts

Ensure the correct size knockout is being used or that the knockout has been fully removed. If using a standard knockout, an appropriate cable gland (ordered separately) is likely required for a secure and sealed fit.

Pros and Cons

Pros

  • Exceptional protection against dust and water ingress (IP66/IP67/IP69).
  • Robust and weather-resistant construction suitable for outdoor and harsh environments.
  • High terminal capacity for various conductor sizes.
  • Sealable lid for enhanced security and environmental protection.
  • Includes external mounting brackets for straightforward installation.

Cons

  • Some cable entry solutions may require the purchase of separate accessories (e.g., AKM).
  • The enclosure is untreated on the surface, which may require consideration depending on the application environment.
  • Installation of M32 entries via knockouts requires specific tools or procedures.

Setup, Compatibility & Care

Setup:

  1. Mounting: Utilize the included external brackets for surface mounting on walls or ceilings. Ensure the mounting surface is stable and capable of supporting the box.
  2. Cable Entry: For rear entries, use the pre-defined M32 knockouts. For other locations, utilize the pre-embossed areas and order appropriate cable glands (e.g., from the LES series) for a secure seal.
  3. Wiring: Connect conductors to the internal clamp, ensuring the correct size (up to 25mm²) is used. Refer to the product's specific terminal capacity details for multiple conductor configurations.
  4. Sealing: Secure the cover by screwing it shut. For added security or environmental sealing, use the integrated sealable features on the lid fasteners.

Compatibility:

  • Suitable for conductors up to 25mm² cross-section.
  • Compatible with accessory cable glands (e.g., AKM, LES series) for varied entry requirements.
  • Designed for use in temperatures ranging from -25°C to 70°C.

Care:

  • Clean the exterior with a damp cloth. Avoid abrasive cleaners that could damage the polycarbonate surface.
  • Periodically inspect cable entries and the cover seal to ensure continued protection against environmental ingress.
  • Ensure all connections remain tight and free from corrosion.

Price History

DatePrice
Visit shop