Safelincs 5DCO Carbon Monoxide Alarm - Digital Display

This compact and slimline carbon monoxide alarm features a 10-year sensor lifespan and is powered ...

Best current price£17.99from Amazon

All Offers

4 offers from £17.99 - £45.00

View price history by clicking the chart icon.

AmazonKidde White 5Dco Digital Carbon Monoxide Alarm And Detector With Aa Batteries - 10 Year Sensor Life Digital Display Co Alarm - 7 Year Warranty
Free delivery in 1–3 days
£17.99
Visit shop
OnBuy.comSafelincs Kidde 5Dco 10 Year Life Digital Display Carbon Monoxide Alarm (1)
Free delivery in 1–3 days
£24.13
Visit shop
B&QB&Q - 5Dco Twin PackDigital 10 Year Life Carbon Monoxide Alarm
Free delivery in 1–3 days
£45.00
Visit shop

Product Information

Full details

This compact and slimline carbon monoxide alarm is designed for domestic use, providing essential safety with its 10-year sensor lifespan and clear digital display. It offers a key benefit of early detection with audible and visual alerts for CO levels, though a minor caveat is its reliance on replaceable batteries rather than a sealed-in unit. Key features include a 10-year sensor, replaceable AA battery power, a digital display showing CO levels from 30ppm, and alarms from 50ppm, all certified to BS EN 50291-1.

All features

Model Part Number5DCO
BrandSafelincs

Extended Product Information

FAQs

How often should I test the alarm?

It is recommended to test the alarm weekly by pressing the test button to ensure it is functioning correctly.

What is the lifespan of the sensor?

The Safelincs 5DCO Carbon Monoxide Alarm features a 10-year sensor lifespan from the date of purchase.

What does the digital display show?

The digital display shows carbon monoxide (CO) levels starting from 30ppm. It will also display messages indicating low battery or end-of-life status.

When does the alarm sound?

The alarm will sound when carbon monoxide levels reach 50ppm. It will also provide a warning "chirp" and digital message for low battery.

Can I use rechargeable batteries?

It is recommended to use high-quality alkaline AA batteries for optimal performance and to avoid potential issues with voltage fluctuations from rechargeable batteries.

What should I do if the alarm sounds?

If the alarm sounds, immediately open all doors and windows to ventilate the area and leave the premises. Do not re-enter until the area is confirmed safe. Seek medical attention if experiencing symptoms of CO poisoning.

How do I clean the carbon monoxide alarm?

Gently dust the alarm with a soft, dry cloth. Avoid using cleaning sprays or solvents, as they can damage the unit or cause false alarms.

Troubleshooting

Alarm does not turn on after inserting batteries.

Check that the batteries are inserted correctly, ensuring correct polarity (+/-). Try a different set of fresh AA batteries. Ensure the battery compartment is securely closed.

Low battery "chirp" and message appear frequently.

Replace both AA batteries with a new set of high-quality alkaline AA batteries. Ensure the batteries are correctly inserted.

False alarm or persistent beeping.

Ensure the alarm is not placed near sources of steam, humidity, or fumes (e.g., kitchens, bathrooms, garages). Check for external factors like extreme temperature changes. If the issue persists, clean the unit as per instructions and test. Contact customer support if necessary.

Digital display is blank or not showing readings.

Check battery power and connection. If batteries are good and connected, remove and reinsert them. If the display remains blank after trying fresh batteries, the unit may be faulty.

Pros and Cons

Pros

  • Long 10-year sensor life reduces maintenance and replacement costs.
  • Clear digital display provides immediate CO level readings.
  • Audible and visual alerts ensure prompt notification.
  • Uses readily available AA batteries for power.
  • Compact and unobtrusive design.

Cons

  • Requires battery replacement, unlike some sealed units.
  • Alarm threshold is 50ppm, which may be higher than some sensitive individuals prefer for immediate alerts.
  • Display shows levels from 30ppm, but alarm triggers at 50ppm.

Setup, Compatibility & Care

Setup:

  1. Ensure the unit is placed in a suitable location, typically on a wall at least 1.5 meters from the floor and away from direct heat sources or vents.
  2. Open the battery compartment and insert the two supplied AA batteries, observing the correct polarity.
  3. The unit will typically perform a self-test upon battery insertion.
  4. Mount the alarm securely to the wall using the provided screws or an appropriate mounting method.

Compatibility:

  • This alarm is designed for domestic use only and is Kitemarked to BS EN 50291-1.
  • It is powered by standard AA batteries.

Care:

  • Cleaning: Dust the alarm regularly with a soft, dry cloth. Never use cleaning sprays or solvents, as they could damage the unit or trigger a false alarm. A vacuum cleaner with a soft brush attachment can be used gently.
  • Battery Replacement: Replace the AA batteries annually, or immediately when the low battery "chirp" and digital message appear. Use only the specified type of AA batteries.
  • Testing: Test the alarm weekly by pressing the test button. Ensure you hear the alarm sound.

Price History

DatePrice
Visit shop