Festo Connecting Cable - NEBC Series - M12 D-coded plug - 1m

The Festo Connecting Cable NEBC (8040451) features an M12x1 D-coded plug conforming to EN 61076-2-...

Best current price£28.59from Tameson UK

All Offers

7 offers from £28.59 - £75.49

View price history by clicking the chart icon.

Tameson UKFesto Connecting Cable Plug M12x1 D-Coded En 61076-2-101 1M - 8040451
Free delivery in 1–3 days
£28.59
Visit shop
RS Components Ltd- UKFesto Cable, NEBC Series, For Use With Fieldbus Modules CTEU
Free delivery in 1–3 days
£34.82
Visit shop

Used Offer

1 offer from £148.34

View price history by clicking the chart icon.

eBayFESTO 8040454 NEBC-D12G4-ES-10-S-R3G4-ET
£15.60 delivery
£148.34
Visit shop

Product Information

Full details

This Festo Connecting Cable from the NEBC series is designed for industrial automation professionals needing reliable Ethernet connectivity. Its key benefit is robust performance in demanding environments, suitable for energy chains and offering versatile protocol support. A potential caveat is its specific M12 D-coded connector, requiring compatible ports.

All features

SeriesNEBC
Model Part NumberNEBC-D12G4-ES-1-S-R3G4-ET
BrandFesto

Extended Product Information

FAQs

What does 'D-coded' refer to on the M12 plug?

'D-coded' refers to the specific keying and contact arrangement within the M12 connector, designed for Ethernet applications. It ensures correct polarity and prevents misconnection with other M12 coding types (e.g., A-coded, B-coded).

Can this cable be used outdoors?

While designed for industrial environments, outdoor use depends on specific environmental ratings (like IP rating) of the cable and connected devices. Consult the product's detailed specifications for suitability in outdoor or exposed conditions.

What is the maximum data rate supported?

This cable is designed for industrial Ethernet protocols. The maximum data rate depends on the specific protocol being used (e.g., EtherNet/IP, PROFINET) and the capabilities of the connected devices, but the cable itself is built to support high-speed industrial communication.

How does the shielding benefit the connection?

The shielding helps to protect the data signal from electromagnetic interference (EMI) and radio frequency interference (RFI) common in industrial environments. This leads to more reliable data transmission and fewer errors.

Is the 1-meter length flexible?

The cable comes in a fixed 1-meter length. For different lengths, other variants within the NEBC series or different Festo cable series may be available.

What is the role of Fieldbus Module CTEU?

Fieldbus Module CTEU is a device designed to interface with Fieldbus networks. The Festo Connecting Cable NEBC is intended to connect these modules to other network components or devices, facilitating communication.

Troubleshooting

No connection detected

Verify both ends of the cable are securely connected. Check that the M12 connector is correctly seated and locked. Ensure the connected devices and network configuration are correct.

Intermittent data loss or errors

Check the cable for physical damage. Ensure the shielding is properly grounded if applicable. Verify that the cable is not subjected to excessive bending radius or stress, especially within energy chains.

Connector difficult to engage/disengage

Ensure the connector is clean and free from debris. Verify that you are using the correct M12 D-coded connector and that the receptacle is not damaged. Do not force the connection.

Pros and Cons

Pros

  • Durable construction for industrial use.
  • Supports multiple common industrial communication protocols.
  • Suitable for dynamic applications like energy chains.
  • Standardized M12 connector ensures broad compatibility with suitable equipment.
  • Shielding provides enhanced signal integrity.

Cons

  • Fixed 1-meter length may not suit all applications.
  • M12 D-coded connector limits compatibility to specific ports.
  • Specific easy-to-clean variants may have different part numbers.
  • Requires compatible Fieldbus Modules CTEU for full functionality.

Setup, Compatibility & Care

Setup:

  1. Ensure the mating connector is an M12x1 D-coded receptacle.
  2. Carefully align the plug with the receptacle and screw the locking nut clockwise until secure.
  3. Connect the other end of the cable to the appropriate Fieldbus Module CTEU or network device.

Compatibility:

  • Connectors: Compatible with M12x1 D-coded sockets (EN 61076-2-101).
  • Protocols: Supports EtherNet, CANopen, I-Port, and RS232.
  • Devices: Designed for use with Festo Fieldbus Modules CTEU and other compatible industrial network devices.

Care:

  • Regularly inspect the cable for signs of wear or damage, especially at connection points and areas prone to flexing.
  • Clean the cable using a soft, damp cloth. Avoid using harsh chemicals or abrasive materials, particularly on easy-to-clean variants to preserve their properties.
  • Ensure connections are clean and free from debris before mating.

Price History

DatePrice
Visit shop