Hensel FK 1610 Junction Box - IP65/66

High-grade thermoplastic junction box with E30/E60/E90 fire resistance rating. Features ceramic te...

Best current price£118.77from Tameson UK

One Offer

1 offer from £118.77

View price history by clicking the chart icon.

Tameson UKHensel Orange Fk 1610 Fire-Rated Junction Box Ip65/66 - Fk 1610
Free delivery in 1–3 days
£118.77
Visit shop

Product Information

Full details

The Hensel FK 1610 Junction Box is designed for electricians and installers requiring a robust, fire-resistant enclosure for electrical connections in demanding environments. Its key benefit is high fire resistance (E30/E90) and IP66 protection, ensuring reliable performance even under extreme conditions. A potential caveat is its specific orange color, which may not suit all aesthetic requirements. This junction box features high-grade thermoplastic construction, ceramic terminals, multiple cable entry points, and a quick-release lid for ease of installation and maintenance.

All features

Model Part NumberFK 1610
BrandHENSEL

Extended Product Information

FAQs

What does the E30/E90 fire resistance rating mean?

This rating indicates that the junction box can maintain its integrity and continue to function for 30 minutes (E30) or 90 minutes (E90) when exposed to fire, ensuring the connected electrical circuit remains operational during that period.

Is this box suitable for outdoor installation?

Yes, with its IP66 rating, it is suitable for protected outdoor installations where it will not be directly exposed to harsh weather conditions like prolonged direct rain or submersion, but it can withstand dust and water jets.

What size cable conductors can be used?

The ceramic terminals are designed to support copper conductors ranging from 1.5mm² to 10mm².

Do I need special tools to install it?

Basic tools for removing knockouts (like a drill or knockout punch) and a screwdriver for tightening terminal screws are typically required. Metric cable glands are also necessary for proper sealing.

What is the purpose of the orange color?

The RAL 2003 orange color is often used for safety-related equipment and can help distinguish electrical components in installations.

Can I use this box for low-voltage applications?

While rated for 400V, the robust construction and high-quality terminals make it suitable for various electrical applications, including low-voltage, provided the wiring and connections are appropriate for the terminal type.

What is the IP rating and what does it signify?

The IP rating is IP66. The first digit (6) means it has the highest level of dust protection (dust-tight). The second digit (6) means it is protected against strong jets of water.

Troubleshooting

Lid is difficult to close or open.

Ensure no wires or debris are obstructing the lid seal. Check that the lid is aligned correctly before attempting to secure the quarter-turn mechanism.

Difficulty inserting cables.

Verify that the correct size metric cable entry knockout has been removed. Ensure you are using compatible metric cable glands that fit the chosen entry size.

Connection terminals feel loose.

Ensure conductors are fully inserted into the ceramic terminals and that the terminal screws are tightened securely. Use conductors within the specified 1.5-10mm² range.

Water ingress observed.

Re-check all cable gland connections and ensure they are tightened correctly onto the box and around the cables. Inspect the lid seal for any damage and ensure the lid is properly closed.

Pros and Cons

Pros

  • Exceptional fire resistance ratings for enhanced safety.
  • High ingress protection (IP66) suitable for challenging environments.
  • Durable construction with quality ceramic terminals.
  • Versatile cable entry options for different installation needs.
  • User-friendly quick-release lid simplifies access.

Cons

  • Distinctive orange color might not blend with all aesthetics.
  • Primarily designed for indoor and protected outdoor use; not for direct weather exposure.
  • Requires specific metric cable glands for optimal sealing.

Setup, Compatibility & Care

Setup:

  1. Identify appropriate cable entries and remove the pre-scored metric knockout sections using appropriate tools.
  2. Insert suitable metric cable glands (not included) into the openings and secure them around the cables.
  3. Connect the copper conductors (1.5-10mm²) to the ceramic terminals according to your wiring diagram.
  4. Route cables through the glands and tighten them to ensure an IP66 seal.
  5. Close the lid, ensuring it clicks into place with the quarter-turn mechanism.

Compatibility:

  • Compatible with copper conductors ranging from 1.5mm² to 10mm².
  • Requires metric cable glands (M25, M32, M40) for maintaining IP rating.
  • Suitable for 400V isolation.

Care:

  • Clean the exterior with a damp, soft cloth. Avoid abrasive cleaners or solvents.
  • Periodically check cable gland seals for integrity, especially if installed in demanding environments.
  • Ensure the lid remains securely fastened to maintain the IP rating.