3X Quad Cat5E Data Wall Outlet Face Plate 4 Port Rj45 Ethernet Network Socket - Loops
Quad RJ45 CAT5e Wall Socket - Supplied with labels Quantity x 3 Overview - These network outlet fa...Quad RJ45 CAT5e Wall Socket - Supplied with labels Quantity x 3 Overview - These network outlet faceplates are a perfect fitting for cables that have been run between rooms beneath floors and behind walls. The faceplate is fitted to a standard double box using the included fixing screws, just like an aerial socket or power outlet. Then network cable can be attached to the RJ45 sockets in just a few minutes, using an IDC termination tool. Simply strip off a short section of the outer cable insulation and follow the colour coded labels on the sockets to push each internal wire into the corresponding connection using an IDC tool (the internal wires on the network cable do not need stripping).The use of IDC connectors, means the socket itself actually pierces the wire’s plastic insulation as it is pushed in, doing away with the need for excessive, intricate wire stripping, thus making installation as easy and fast as possible. The colour coding on the side of each port is TIA/EIA-568B. They can be wired in the A format if required however colour coding for the A format is not illustrated on the product itself and a wiring diagram would be required. Types of Wiring - Depending on the application in which you hope to use it, the socket can be wired in both the ‘straight through’ or ‘cross-over’ configurations. 'Cross over' wiring is usually used for connecting 2 computers directly to one another, without the use of a Hub or Router. They use TIA/EIA-568-A wiring at one end, and TIA/EIA-568-B at the other.'Straight through' cables can be used for connecting a PC or games console to a Hub/Router, or, in conjunction with AV extender devices, for audio and video distribution throughout a home or commercial project. To create a 'Straight through' cable, it should be wired using the same wiring variant at both ends. Either ‘TIA/EIA-568-A to TIA/EIA-568-A’ or ‘TIA/EIA-568-B to TIA/EIA-568-B’SpecificationCan be used over distances up to 100m/328ft for networking purposesTIA.
Loops 3X Quad Cat5e Data Wall Outlet Face Plate 4 Port Rj45 Ethernet Network SocketFree delivery in 1–3 days£24.49Visit shop →
Product Information
Full details
This product guide is for installers and DIY enthusiasts looking to create clean, integrated network connections within a building. The key benefit is a simplified, professional termination of Cat5e Ethernet cables behind walls or floors. A caveat is that an IDC termination tool is required for installation, which is not included.
All features
Brand
Loops
Extended Product Information
FAQs
What tools are needed for installation?
You will need an IDC termination tool to connect the wires to the RJ45 sockets and a screwdriver for mounting the faceplate to the electrical box. A network cable tester is also recommended for verification.
Can I use this with Cat6 cables?
While Cat5e is specified, Cat6 cables may physically fit. However, to ensure optimal performance and adherence to standards, it is recommended to use Cat5e cables with Cat5e rated outlets.
Do I need to strip the wires before using the IDC tool?
No, the IDC connectors are designed to pierce the wire insulation, so the internal wires do not need to be stripped beforehand.
How do I wire for a 'cross-over' connection?
To create a 'cross-over' connection, you need to wire one end of the cable using the TIA/EIA-568A standard and the other end using the TIA/EIA-568B standard. Note that the A format color coding is not shown on the product itself.
What is the maximum cable length supported?
These sockets support standard networking distances up to 100 meters (328 feet).
How many faceplates are included in this pack?
This pack includes three Quad Cat5e Data Wall Outlet Face Plates.
Troubleshooting
Network connection is slow or intermittent.
Verify that all wires are correctly seated in the IDC terminals and that the correct TIA/EIA wiring standard was followed at both ends of the cable run. Ensure the cable is not damaged and is within the 100m maximum length.
No network connectivity.
Double-check the wiring against the color code or wiring diagram. Ensure the cable is properly terminated at both the faceplate and the patch panel or router. Test the cable with a network cable tester if available.
Difficulty inserting wires into IDC terminals.
Ensure you are using a proper IDC termination tool. Apply firm, steady pressure to seat the wire completely. Make sure the wire ends are cut cleanly.
Pros and Cons
Pros
Streamlines network cable termination for a tidy, professional finish.
IDC connectors simplify the installation process, saving time and effort.
Four ports per faceplate offer good connectivity density.
Compatible with standard wiring practices (TIA/EIA-568B) and offers flexibility for crossover connections.
Cons
Requires a separate IDC termination tool for installation.
Color coding for TIA/EIA-568A format is not illustrated on the product.
Faceplates are designed for standard double-gang boxes; compatibility with other box sizes may vary.
Setup, Compatibility & Care Instructions
Setup:
Ensure you have a standard double-gang electrical box installed at your desired location.
Prepare your Cat5e network cable by stripping a small section of the outer insulation, leaving the internal wires exposed.
Using an IDC termination tool, push each internal wire into the corresponding color-coded slot on the back of the RJ45 socket according to the TIA/EIA-568B standard (or TIA/EIA-568A if preferred, consulting a wiring diagram).
Secure the faceplate to the double-gang box using the provided fixing screws.
Compatibility:
Compatible with standard Cat5e Ethernet cables.
Designed to fit standard double-gang electrical boxes.
Supports TIA/EIA-568A and TIA/EIA-568B wiring standards.
Care:
Clean the faceplate with a soft, dry cloth. Avoid using abrasive cleaners or solvents, which could damage the plastic.