The PegDev Detectable Underground Warning Tape (Sewer Pipe) is a premium quality marker tape speci...The PegDev Detectable Underground Warning Tape (Sewer Pipe) is a premium quality marker tape specifically designed for marking buried pipes and underground services. This tape is engineered to provide a clear and visible warning of the presence of sewer pipes during excavation work, helping to prevent accidental damage. The tape is manufactured from durable 130-micron thick Polypropylene, offering excellent strength and resistance to wear and tear in harsh underground conditions. It is coloured red for high visibility and features two stainless steel wires embedded within, making it fully detectable from the surface using standard detection equipment. This unique design ensures that the tape can be quickly located before any excavation or digging begins, significantly reducing the risk of damaging underground infrastructure. The PegDev Detectable Underground Warning Tape complies with the EN 12613 standard, ensuring it meets all necessary safety and performance regulations. Its rot-resistant properties make it ideal for long-term installations, providing peace of mind that your services are properly marked and detectable for years to come. Whether you're a professional contractor or a DIY enthusiast, this tape is an essential tool for any project involving buried pipes or cables.
The Pegdev Detectable Underground Warning Tape (Sewer Pipe) is designed for contractors and DIYers needing to clearly mark buried sewer pipes. Its primary benefit is preventing accidental damage during excavation by providing a visible and detectable warning. A potential caveat is its specific use case for sewer pipes, requiring different tapes for other utilities. This tape is constructed from durable 130-micron polypropylene, features embedded stainless steel wires for detectability, and is colored red for high visibility, ensuring compliance with EN 12613 standards and offering rot-resistant, long-term protection.
All features
Brand
Pegdev
Extended Product Information
FAQs
What is the primary purpose of this warning tape?
Its primary purpose is to clearly mark the location of buried sewer pipes to prevent accidental damage during excavation activities.
How is this tape detectable?
The tape contains two embedded stainless steel wires that can be detected on the surface using standard electronic locating equipment.
What material is the tape made from?
The tape is manufactured from durable 130-micron thick Polypropylene.
Does this tape comply with any safety standards?
Yes, it complies with the EN 12613 standard for underground warning tapes.
Can I use this tape for water pipes or gas lines?
This specific tape is designed and colored for sewer pipes. It is recommended to use specific colored warning tapes designated for other utilities like water or gas to avoid confusion.
How long will the tape last underground?
The tape is rot-resistant and made from durable material, designed for long-term installation and protection of buried services.
What is the recommended installation depth?
Typically, the tape is laid approximately 300mm above the buried pipe, with at least 150mm of soil cover before backfilling.
Troubleshooting
Tape is not detectable by locating equipment.
Ensure the locator is set to the correct frequency for steel wires and that the tape is properly buried and not obstructed by other metallic objects. Verify the tape is not damaged.
Tape appears to be damaged or torn.
If damage occurs during installation, splice or replace the damaged section if possible. For significant damage, consider re-installing a new section.
Visual identification is difficult due to depth or soil conditions.
Ensure the tape is installed at the recommended depth and that the soil cover is appropriate. The red color provides primary visibility; electronic detection is the secondary, more reliable method for deep or obscured lines.
Pros and Cons
Pros
Ensures clear and immediate identification of buried sewer lines.
Dual detection method (visual and electronic) significantly reduces risk of accidental damage.
Durable construction withstands harsh underground conditions.
Compliant with safety standards (EN 12613).
Long-lasting due to rot-resistant properties.
Cons
Primarily designed for sewer pipes; requires specific tapes for other utilities.
Requires specialized detection equipment for electronic locating.
Length of 8 meters may be insufficient for very large projects.
Setup, Compatibility & Care
Setup:
Ensure the ground is clear of sharp objects that could damage the tape.
Lay the tape directly above the buried sewer pipe, following local regulations for placement depth and distance from the pipe (typically 300mm above the pipe).
Cover the tape with a minimum of 150mm of soil or sand before backfilling the trench.
Compatibility:
The stainless steel wires are compatible with standard electromagnetic pipe and cable locators.
Care:
Store the tape in a cool, dry place away from direct sunlight before installation.
Once installed, the tape requires no ongoing maintenance as it is designed for long-term burial.