Omron Timer Relay - H3DK-M1

DIN-rail mountable timer relay featuring 8 operating modes and 8 time ranges from 0.1 seconds to 1...

Best current price£35.00from eBay

All Offers

6 offers from £35.00 - £190.98

View price history by clicking the chart icon.

eBayOMRON H3DK-M1 Time Relay 24-240v 0.1s-1200h
£3.65 delivery
£35.00
Visit shop
Tameson UKOmron H3dk-M1a Multi-Mode Din Rail Timer 12Vdc - H3dk6014m
Free delivery in 1–3 days
£70.35
Visit shop
Blueperry agriculture (UK)Omron Multifunc Timer, 12 Vdc, Spdt H3dkm1a12vdc
Free delivery in 1–3 days
£146.88
Visit shop

Used Offer

1 offer from £91.20

View price history by clicking the chart icon.

Product Information

Full details

The Omron H3DK-M1 Timer Relay is designed for industrial automation and control applications requiring precise timing functions. It offers a broad range of operating modes and time settings, adaptable to various tasks like sequential operations or delayed power activation. A key benefit is its multi-voltage compatibility, simplifying installation in diverse power environments. However, its IP30 protection rating means it should be used in protected control panels and not exposed to harsh environmental conditions.

All features

SeriesH3DK-M1
Model Part NumberH3DK6001H
BrandOmron

Extended Product Information

FAQs

What is the main function of the Omron H3DK-M1 Timer Relay?

It is used to control the timing of electrical operations in industrial automation, offering various delay and interval functions based on selected modes and time ranges.

Can this timer relay be used with different voltage systems?

Yes, it supports a wide input voltage range of 24-240V AC/DC, making it compatible with most standard industrial power supplies.

What is the maximum load the output relay can handle?

The single pole double throw (SPDT) output relay is rated for a maximum of 5A.

How do I select the operating mode and time range?

Operating modes and time ranges are selected using the rotary switches located on the front panel of the relay.

What kind of environment is this timer relay suitable for?

It has an IP30 protection rating, meaning it is suitable for installation inside control cabinets or enclosures where it is protected from dust and direct contact.

How is the H3DK-M1 mounted?

It is designed for easy mounting on a standard 35mm DIN rail.

What types of timing functions does it offer?

It offers multiple timing functions including ON-delay, OFF-delay, interval, and one-shot output modes.

Troubleshooting

Unit does not power on.

Verify the power supply voltage is within the 24-240V AC/DC range and that the power connections are secure.

Relay does not switch at the expected time.

Double-check the selected operating mode and time range settings. Ensure the input signal is correctly applied to initiate the timing sequence.

Output relay does not energize or de-energize.

Confirm that the selected mode allows for output activation under the current conditions. Check that the load connected to the output does not exceed the 5A rating.

Timing is inconsistent.

Ensure a stable power supply is provided. Check for external interference that might affect the unit's performance.

Pros and Cons

Pros

  • Versatile timing options with 8 operating modes and 8 time ranges.
  • Wide voltage input range (24-240V AC/DC) simplifies power selection.
  • Compact DIN-rail mount design for easy integration into control panels.
  • Reliable SPDT output relay suitable for common control tasks.
  • Durable construction for industrial applications.

Cons

  • Limited environmental protection (IP30) requires installation in clean, dry locations.
  • Only one output relay contact, which may be insufficient for complex switching requirements.
  • User interface for mode and range selection might require careful reading of the manual for initial setup.

Setup, Compatibility & Care

Setup:

  1. Mounting: Securely attach the H3DK-M1 relay to a standard 35mm DIN rail.
  2. Wiring: Connect the power supply to the appropriate terminals (24-240V AC/DC) and wire the control signals and output load according to the terminal layout diagram in the product manual.
  3. Mode and Range Selection: Use the rotary switches on the front panel to select the desired operating mode and time range.
  4. Power Up: Apply power to the unit. The relay will begin its timing sequence based on the selected settings.

Compatibility:

  • Power Supply: Compatible with 24-240V AC/DC power sources.
  • Output Load: Suitable for loads up to 5A. Ensure the connected load does not exceed this rating.
  • Environment: Designed for use in control panels with an IP30 rating; avoid exposure to moisture, dust, or corrosive substances.

Care:

  • Keep the unit clean and free from dust accumulation. A dry or slightly damp cloth can be used for cleaning. Avoid using solvents.
  • Ensure wiring connections remain secure and free from corrosion.
  • Periodically check the operation to ensure it meets timing requirements.

Price History

DatePrice
Visit shop