ABB SwitchLine Disconnector - OT40FT3 - 40A

This 3-pole ABB load breaker from the SwitchLine OT series can be used as both a load breaker and ...

Best current price£74.42from eBay

One Offer

1 offer from £74.42

View price history by clicking the chart icon.

eBayInsulated Disconnect Switch 3P 40A Non Drive 1SCA104940R1001
£13.20 delivery
£74.42
Visit shop

Product Information

Full details

This guide is for electricians, maintenance professionals, and system integrators working with electrical control systems. The ABB SwitchLine Disconnector OT40FT3 offers reliable load breaking and main switching capabilities for demanding applications. A key consideration is its maximum operating temperature of +40°C, requiring careful environmental planning.

All features

SeriesSwitchLine OT
Model Part NumberOT40FT3 1SCA104940R1001
BrandABB

Extended Product Information

FAQs

What is the maximum voltage this disconnector can handle?

The maximum rated operating voltage (Ue) for this disconnector is 750V AC.

Can this switch be used as a main isolator?

Yes, this ABB SwitchLine disconnector is designed to be used as both a load breaker and a main switch.

What is the maximum continuous current rating?

The rated continuous current (Iu) is 40A.

Does this disconnector include fuses?

No, this is a non-fused isolator. Overcurrent protection must be provided separately.

What is the power rating at 400V for AC-3 and AC-23 applications?

The rated operation power at AC-3 and AC-23, 400V is 11kW.

What type of terminals does it use for the main circuit connection?

It uses screw connections for the main circuit electrical connection.

What is the environmental protection rating?

The degree of protection on the front side is IP20.

What is the maximum ambient operating temperature?

The maximum operating temperature is +40°C.

Troubleshooting

Switch is difficult to operate

Check for obstructions around the operating mechanism. Ensure the switch is properly mounted and not under mechanical stress. Verify ambient temperature is within operational limits.

Overheating at terminals

Ensure all connections are torqued to the manufacturer's recommended specification. Check conductor size compatibility with terminal capacity. Clean terminals if corrosion is present.

No power through the switch

Verify that the upstream circuit breaker or fuse is closed/unbroken. Check all connections to and from the switch for continuity. Ensure the switch is in the 'ON' position.

Device does not switch off power

Confirm the switch is fully actuated to the 'OFF' position. Check for internal damage or misalignment. If issues persist, the unit may need replacement.

Pros and Cons

Pros

  • Dual functionality as load breaker and main switch
  • High power switching capability (11kW)
  • Robust 40A continuous current rating
  • Suitable for 3-phase systems
  • Secure screw terminal connections

Cons

  • Limited maximum operating temperature (+40°C)
  • No integrated auxiliary contacts
  • Requires separate control element
  • IP20 protection is basic; not suitable for wet environments without further protection

Setup, Compatibility & Care

Setup: This device is designed for fixed built-in technique and panel mounting. Ensure the mounting surface is clean and stable. Connect the main circuit conductors to the screw terminals, following proper torque specifications for secure connections. The switch is operated manually via its designated interface (not included as part of this specific model). Ensure proper grounding of the enclosure.

Compatibility: The OT40FT3 is compatible with standard 3-phase electrical systems operating within its voltage range (up to 750V AC). It is suitable for installation in distribution boards. Note that this is a non-fused isolator; appropriate overcurrent protection (fuses or circuit breakers) must be installed separately upstream of this device as per local electrical codes and safety standards.

Care: Keep the device clean and free from dust and debris. Use a dry or slightly damp cloth for cleaning; avoid solvents. Periodically inspect connections for tightness and signs of corrosion. Ensure ventilation around the unit is adequate, especially considering its maximum operating temperature of +40°C.