Eaton CI Switch Box Empty - 206896

Eaton Moeller series CI-K Insulated enclosure, HxWxD=200x120x160mm, +mounting plate. This enclosur...

Best current price£15.34from RS Components Ltd- UK

All Offers

47 offers from £15.34 - £138.36

View price history by clicking the chart icon.

RS Components Ltd- UKEaton Mounting Kit for Use with +L, +NHI-E, +U, A, NHI, PKZM01, VHI-PKZ01
Free delivery in 1–3 days
£15.34
Visit shop
Rapid Online - Rapid Electronics Ltd.Eaton 289936 CI/E-PKZ01-XG Transparent enclosure insert for casing
Free delivery in 1–3 days
£15.48
Visit shop
Tameson UKEaton Industries Ci Switch Box Empty - 206881
Free delivery in 1–3 days
£23.22
Visit shop
eBayEaton XTPAXENCS41 Insulated Enclosure For Motor Protective Switch CI-K2-PKZ0
Free delivery in 1–3 days
£29.99
Visit shop
Blueperry agriculture (UK)Eaton Empty Plastic Cabinet Din Rail Cik195ts
Free delivery in 1–3 days
£52.94
Visit shop

Used Offers

5 offers from £31.01 - £84.55

View price history by clicking the chart icon.

eBayEaton CI-K2-100-M Moeller Chassis
£15.60 delivery
£31.01
Visit shop

Product Information

Full details

The Eaton CI-K3-160-M is an insulated polycarbonate enclosure designed for industrial applications, offering robust protection for electrical components and mounting plates. Its IP65 rating ensures suitability for challenging environments. While it provides excellent durability and safety, users should note its fixed dimensions and the specific cable entry types available.

All features

Model Part Number206896
BrandEaton

Extended Product Information

FAQs

What does IP65 rating mean?

An IP65 rating means the enclosure is dust-tight and protected against water jets from any direction. This makes it suitable for demanding industrial environments.

What material is the enclosure made of?

The enclosure is constructed from durable Polycarbonate (PC) and plastic, offering good resistance to impacts and environmental factors.

Can I install custom-sized cable glands?

The enclosure is pre-designed for M20 and M25 cable glands. While knock-outs can be removed, custom sizes outside these standards might require modification and could compromise the IP rating.

What is the maximum temperature the enclosure can withstand?

The enclosure can operate in a temperature range from -25 °C to +70 °C.

Does the enclosure come with a mounting plate?

Yes, the Eaton CI-K3-160-M enclosure includes a mounting plate for the convenient installation of electrical components.

How much power can be dissipated by the enclosure?

The enclosure has a dissipative power loss rating of 25.5 W.

What colors are available for this enclosure?

This enclosure is typically available in factory colors: Grey-white (RAL 7035) and Black (RAL 9005).

Troubleshooting

Enclosure not sealing properly

Check the lid seal for debris or damage. Ensure all latches/screws are fully tightened. Replace the seal if it is worn or cracked.

Difficulty making cable entries

Use appropriate tools to cleanly remove the knock-out sections for M20/M25 cable glands. Ensure glands are compatible with the enclosure material.

Internal components overheating

Verify that the total power dissipation of internal components does not exceed 25.5 W. Consider ventilation or alternative cooling if necessary, though this enclosure is not designed for active ventilation.

Mounting plate alignment issues

Ensure components are correctly aligned and secured to the mounting plate before installing the plate into the enclosure. Check for any obstructions.

Pros and Cons

Pros

  • High IP65 ingress protection for dust and water resistance.
  • Durable polycarbonate construction for longevity in industrial settings.
  • Multiple cable entry options (M20/M25) allow for flexible wiring.
  • Includes a mounting plate for simplified component installation.
  • Wide operating temperature range suitable for various environments.

Cons

  • Fixed dimensions may not suit all installation requirements.
  • Limited options for custom cable entry sizes.
  • Power loss rating of 25.5 W might be a constraint for high-power dissipation needs.
  • Color options are limited to factory colors (Grey-white and Black).

Setup, Compatibility & Care

Setup:

  1. Component Mounting: Utilize the pre-installed mounting plate to secure internal components such as control relays, terminal blocks, or small power supplies using appropriate screws.
  2. Cable Entry: For cable entry, remove the knock-out sections at the designated M20/M25 points on the top, bottom, or rear of the enclosure. Install suitable cable glands (not included) to maintain the IP65 rating.
  3. Enclosure Sealing: Ensure the enclosure lid is securely fastened with its integrated latches or screws to maintain the IP65 rating.

Compatibility:

  • The enclosure is designed to be compatible with standard industrial electrical components, including emergency stop buttons and devices requiring a mounting plate.
  • It accommodates standard M20 and M25 cable glands.
  • Note the maximum operating temperature of +70 °C and minimum of -25 °C.

Care:

  • Clean the exterior with a soft, damp cloth. Avoid abrasive cleaners or solvents, which can damage the polycarbonate material.
  • Periodically inspect the enclosure seal and cable glands to ensure the IP65 rating is maintained. Replace any damaged seals or glands.
  • Ensure internal components do not exceed the 25.5 W power dissipation limit to prevent overheating.