Schneider Electric Canalis Branch Box - KSB32CP

Schneider Electric Canalis KS junction box, white, (WxHxL) 108x165x437.5mm, junction mode socket, ...

Best current price£129.51from Tameson UK

One Offer

1 offer from £129.51

View price history by clicking the chart icon.

Tameson UKSchneider Electric White Canalis Branch Box Busbar Sleeve - Ksb32cp
Free delivery in 1–3 days
£129.51
Visit shop

Product Information

Full details

This Schneider Electric Canalis KS junction box (KSB32CP) is designed for medium power distribution in commercial and industrial settings, offering a robust solution for tapping off from busway trunk systems up to 32A. Its key benefit is a high degree of protection (IP55) against dust and water projections, ensuring reliable operation in challenging environments. A potential caveat is its specific application for busway systems, requiring compatible infrastructure.

All features

Model Part NumberKSB32CP
BrandSchneider Electric

Extended Product Information

FAQs

What is the primary function of the KSB32CP?

The KSB32CP is a tap-off unit designed to draw power from a Schneider Electric Canalis KS busway trunk for supplying downstream equipment.

What does IP55 protection mean?

IP55 means the unit is protected against dust ingress and low-pressure water jets from any direction, making it suitable for environments with moderate dust and occasional water splashes.

Can this unit be used with any busway system?

No, this unit is specifically designed for compatibility with Schneider Electric Canalis KS busway systems.

What is the maximum current this unit can handle?

The unit has a nominal rated current of 32A at 50 Hz.

Does the unit include an earth connection?

The unit is described as having 4 conductors (excluding earth), indicating that a separate earth connection must be provided through the busway system or other means.

Is this product suitable for outdoor use?

While the IP55 rating offers protection against dust and water projections, it is primarily designed for commercial and industrial building applications. Check specific environmental ratings and local regulations for outdoor installations.

How easy is it to install?

The product is designed for quick, light, and easy assembly, simplifying the installation process.

Troubleshooting

Unit does not provide power.

Verify that the busway system is energized. Ensure the KSB32CP is correctly seated and locked onto the busway. Check internal connections if accessible and safe to do so, following all safety precautions.

Water ingress observed.

Immediately de-energize the busway. Inspect the enclosure seals and connection points for damage. Ensure the unit is properly closed and secured. Contact Schneider Electric support if damage is found.

Overheating at connection point.

De-energize the system. Check for loose connections within the tap-off unit or on the busway. Ensure the rated current (32A) is not exceeded. Clean connection surfaces if necessary. Consult a qualified electrician.

Difficulty attaching unit to busway.

Ensure you are using a compatible Canalis busway system. Check for any obstructions or debris on the busway or the unit's connection interface. Refer to the specific installation manual for the busway system.

Pros and Cons

Pros

  • High ingress protection (IP55) for durability in harsh conditions.
  • Suitable for medium power distribution up to 32A.
  • Designed for easy and quick installation.
  • Environmentally conscious product designation (Green Premium).
  • High nominal voltage rating (690V) for broad applicability.

Cons

  • Primarily designed for busway trunk systems, limiting standalone use.
  • Requires compatible busway infrastructure for integration.
  • Specific connector types might be required depending on the busway system.
  • Excludes earth conductor from the 4 specified conductors, requiring separate earth connection.

Setup, Compatibility & Care

Setup:

Installation of the KSB32CP involves securely attaching it to a compatible Schneider Electric Canalis busway system. Ensure the busway is de-energized before proceeding. The unit is designed for a quick connection process, typically involving sliding the tap-off unit onto the busway and engaging the connection mechanism according to the busway system's specific instructions.

Compatibility:

This junction box is specifically designed for use with Schneider Electric Canalis KS busway systems rated for 32A. Verify that the busway's profile and connection interface match the KSB32CP.

Care:

To maintain optimal performance and longevity:

  1. Periodically inspect the unit for any signs of damage or wear.
  2. Ensure the enclosure remains securely fastened to prevent dust or water ingress.
  3. Clean the exterior with a slightly damp cloth. Avoid using abrasive cleaners or solvents.
  4. Regularly check connections within the busway system, following the busway manufacturer's maintenance schedule.

Price History

DatePrice
Visit shop